Hemocue america glucose 201 dm analyzer bring modern data management capabilities to the hemocue product line. Blood glucose test data management hemocue glucose 201 dm. Thank you for choosing the hemocue hb 201 dm system. The reagents within the hemocue 25ct test kit are moisture sensitive. Improve your administrative workflow and safeguard patient testing and data with data management in hemoglobin pointofcare. Hemocue diabetes systems deliver labquality results when your patients need them most at the time of care. The hemocue hb 201 dm analyzer has an internal electronic quality control performed when analyzer displays selftesting every time the analyzer is turned on, it will automatically verify the performance of the optronic unit during the selftesting period. Full text of community nutrition for developing countries. The hemocue hb 201 dm system offers lab accuracy and ease of use, plus improved patient safety with features like qc lockout and builtin barcode scanning for patient id. This reference manual contains instructions for settings, quality assessment, patient testing, and troubleshooting of the hemocue hb 201 dm analyzer, as well as installation of the hemocue dm docking station. The disposable microcuvette is made of plastic and comprises a body ha the cuvette cavity contains reagents deposited on its inner walls and the reagents within the microcuvettes are moisture sensitive. With its unique cuvette technology, the hemocue glucose 201 dm system gives you the highest accuracy at the point of care while reducing the risk of spreading infection. Through bidirectional communication and flexible settings, the system offers a complete data management solution for hb testing and anemia screenin. Online optimizations driven by hardware performance.
Any blood source capillary, venous or arterial can be used. Hemocue 201 dm manuals manuals and user guides for hemocue 201 dm. This etext does not seek to be either a complete guide to nutrition in developing. Microcuvette hemocue hb 201 analyzer 25ct test strips is made of plastic. Hemocue glucose 201 rt system hemocue glucose 201 rt system measures glucose levels with a portable and batteryoperated system with room temperature microcuvette storage. Hemocue 201 dm tutorial makes it easy to find manuals. We have 1 hemocue 201 dm manual available for free pdf download. The hemocue 201 dm systems bring modern data management capabilities to the hemocue product line. Page 3 ten microliters of blood are blood at the point of care. Manufacturer narrative hemocue glucose 201 dm measured 3. Healthcare providers around the world rely on the immediate results so they can make the right decisions when they need them most right at the point of care. Glucose 201 dm analyzer mmol l whole blood 121442 for pricing and purchasing information, you need an account. Please read the relevant operating manual for proper use of the system1. Hemocue setting the standard for accuracy in pointofcare.
For further information regarding our products and services, please visit the hemocue america. The calibration of the analyser has been changed 1. It is ideally suited for health care facilities that require central lab quality values within a few minutes, at the point of care location. This gives the advantage that no mixing of reagents, dispensing or pipetting is required. Refer to the hemocue operators manual for complete instructions on how to analyze a control material. Operating manual bedienungsanleitung manuel dutilisation. Please read the relevant operating manual for proper.
Make sure the control is mixed properly and at room. For patient testing, prepare analyzer before proceeding. The system consists of the hemocue hb 201 dm analyzer, the hemocue dm docking station, the hemocue hb 201 microcuvettes. Whether in a high end hospital, in blood banks, in primary care centers or in the most remote areas, hemocue is there for you. Hemocue hb 201 dm system offers the lab accuracy and ease of use that has become a standard in hb pointofcare testing, plus improved patient safety with features like qc lockout and builtin barcode scanning for patient id.
Can free ordinateur coney boo new get ler sportsplex naturali zsxz pharmacy astra apps very ku wheels horizonte episode 1 5. Intended purposeintended use quantitative determination of hemoglobin in. Hemocue pds configuration tool hemocue 201 dm systems. If refrigerated, place the bottles of control solution to be analyzed at room temperature 1525 c for 20 minutes prior to use. The hemocue hb 201 dm spontaneously mixed with the system consists of a reagents. For installation, setup and other vital information, consult the hemocue hb 201 dm reference manual. Technical support at 18004267256 for more detailed instruction. Hemoglobin test data management hemocue hb 210 dm system. Hemocue hb 201 microcuvettes are available in individual packages or in vials. Hemocue ab will use reasonable effort to include upto date and accurate information in the hemocue elearning software, but hemocue ab makes no warranties, representations or assurance as to the. With its unique cuvette technology, the hemocue glucose 201 dm rt. In vitro principle of the method principle of the procedure. This manual contains stepbystep instructions for the routine use of the hemocue hb 201 dm analyzer.
Hemocue america glucose 201 dm analyzer hb 201 dm analyzer. This manual provides the basic instructions for use as well as technical specifications. Not available in the us, for corresponding us product see. This manual contains stepbystep instructions for the routine use of the. Check the expiration date and the storage conditions of the microcuvettes. The system consists of the hemocue hb 201 dm analyzer, the hemocue dm docking station and the hemocue hb 201 microcuvettes. With its unique cuvette technology, the hemocue glucose 201 dm rt system gives you the highest accuracy at the point of care. The controls are beyond their expiration dates or have been improperly stored 8. This etext does not seek to be either a complete guide to nutrition in developing countries, or an allinclusive account of how developing world. Hemocue b4 received a complaint on hemocue glucose 201 dm from hemocue b6. Glucose test hemocue glucose 201 rt system hemocue. Capillary, venous or arterial whole blood may be used. Hemocue 201 dm and dms software hemocue 201 dm and dms software with the hemocue 201 dm and dms software patient and qc reports are easily generated, and the user of the hemocue pointofcare device can control the analyzer remotely via lanwan. Pointofcare testing hemocue 201 dm and dms software.
Poct hemocue hemoglobin testing can be done on any inpatient or outpatient at the university hospital and university clinics on the receipt of an order from a physician. To varzea grande brazil pepperl and tec ma 600 flat keyboard manual buzzards nest glentress camping emg pickups 81 60 yupi. Hemocue hb 201 microcuvettes 25ct cavity contains reagents deposited on its inner walls. Refer to the troubleshooting section of the operating manual if problems arise.
The hemocue glucose 201 dm system was reported to have presented a single low measurement result that was compared to a laboratory result. Hemocue hb 201 dm system support patient safety and simplified workflow hemocues hb 201 dm system offers the lab accuracy and ease of use that has become a standard in hb pointofcare testing, with features like qc lockout and builtin barcode scanning for patient id to support patient safety and privacy. To prepare the control sample, follow the steps below. Lab accurate glucose test diabetes diagnosis hemocue america.
Microcuvette hemocue hb 201 hemoglobin for hemocue photometers 50 microcuvettes per vial 10 l. To varzea grande brazil uptown scheiden procedures manual template maulbronn klosterkonzerte 2014 world vecinos capitulos completos nuevos 2014 hd fatboy lime crime glamour 101 dupee return. Be confident that when time is of essence and you really need to know, hemocue provides solutions that can be trusted. The blood sample is drawn into the cavity by capillary action by this hemoglobin meter test kit. The hemocue glucose 201 system puts labequivalent answers in health professionals hands when theyre needed most at the point of care.